Total System Protection

 

Connect Inject

Connect Inject

Video Overview

Oeo08I-bTMA

A/C Re-New Connect Inject

• Revitalizes and energizes air conditioning systems • OEM approved for aiding sticking valves • Quiets noisy systems and lowers energy usage • Aids oil return/heat transfer with R-407C and R-22 drop-ins • Quick one-time disposable injector • Treats up to 5 tons; for systems 5-10 tons, use two treatments

A/C ReStart Connect Inject

• POE lubricant treatment specifically for R-22 retrofits • Eliminates oil change-out by boosting oil return • Rx-Acid Scavenger technology addresses trace acids at retrofit • Quick one-time disposable injector • Treats up to 5 tons; for systems 5-10 tons, use two treatments

Rx-Acid Scavenger Connect Inject

• For normal preventative maintenance or after compressor burnouts • Removes existing acid and prevents future acid • New synthetic formula improves scavenging of acid by-products • Quick one-time disposable injector • One injector per residential A/C system, or gallon of oil in commercial systems

Packaging Size Part Number
A/C Re-New Connect Inject 4057-56
A/C ReStart Connect Inject 4060-56
Rx-Acid Scavenger Connect Inject 4301-06
Connect Injector Tool 4155-01

Directions for A/C Re-New Connect Inject

This product must be used in accordance to the following directions by HVACR professionals only.

1. Make sure system is running and low side and high side service ports are properly identified. If unit is a heat pump, be sure it is in cooling mode. Remove caps from the Connect Inject.

2. Make sure isolation valve on Connect Injector (4155-01) is turned off and connect to low side service port. Barely screw on Injector, briefly open valve to purge hose and then tighten.

3. Connect high side (red) line of manifold gauge set to the high side service port. Briefly crack open high side manifold valve to purge air out of the yellow hose. Close high side manifold valve, then quickly tighten yellow hose fitting to the A/C Re-New Connect Inject.

4. Open isolation valve on Connect Injector. Over the next minute, with the vessel in a vertical position, slowly modulate high pressure through injector by opening high side manifold valve so product flows into system. Close manifold valve and allow a few seconds for Injector to stabilize to low side pressure.

5. Remove manifold and Injector from the system service ports and replace caps. Remove Connect Injector Tool so it can be used for the next installation – do not discard. Properly discard black colored Injector.

Directions for A/C ReStart Connect Inject

1. Make sure system is running and low side and high side service ports are properly identified. If unit is a heat pump, be sure it is in cooling mode. Remove caps from the Connect Inject.

2. Make sure isolation valve on Connect Injector (4155-01) is turned off and connect to low side service port. Barely screw on Injector, briefly open valve to purge hose and then tighten.

3. Connect high side (red) line of manifold gauge set to the high side service port. Briefly crack open high side manifold valve to purge air out of the yellow hose. Close high side manifold valve, then quickly tighten yellow hose fitting to the A/C ReStart Connect Inject. See Figure 1.

4. Open isolation valve on Connect Injector. Over the next minute, with the vessel in a vertical position, slowly modulate high pressure through injector by opening high side manifold valve so product flows into system. Close manifold valve and allow a few seconds for Injector to stabilize to low side pressure.

5. Remove manifold and Injector from the system service ports and replace caps. Remove Connect Injector Tool so it can be used for the next installation – do not discard. Properly discard black colored Injector.

Note: Use two injectors for systems between 5-10 tons in size. For air conditioning systems larger than 10 tons, a minimum 15% of the oil charge needs to be A/C ReStart. Remove equal amount of existing oil first.

Directions for Rx-Acid Scavenger Connect Inject

Shake can well. Make sure system is running and low side is below 65 psi.

1. Make sure system is running and low side and high side service ports are properly identified. If unit is a heat pump, be sure it is in cooling mode. Remove caps from the Connect Inject.

2. Make sure isolation valve on Connect Injector (4155-01) is turned off and connect to low side service port. Barely screw on Injector, briefly open valve to purge hose and then tighten.

3. Connect high side (red) line of manifold gauge set to the high side service port. Briefly crack open high side manifold valve to purge air out of the yellow hose. Close high side manifold valve, then quickly tighten yellow hose fitting to the Rx-Acid Scavenger Connect Inject.

4. Open isolation valve on Connect Injector. Over the next minute, with the vessel in a vertical position, slowly modulate high pressure through injector by opening high side manifold valve so product flows into system. Close manifold valve and allow a few seconds for Injector to stabilize to low side pressure.

5. Remove manifold and Injector from the system service ports and replace caps. Remove Connect Injector Tool so it can be used for the next installation – do not discard. Properly discard black colored Injector.

Literature Downloads

Download the product bulletin and other relevant literature here.

Labels

Download a low resolution file of the product label here.

SDS Information

Read and understand the product’s Safety Data Sheet for precautionary and first aid information.